Skip to content
Mind PowerSolar & Water Solutions, Ballari
Racold split heat pump water heater with outdoor unit and storage tank
Racold

Racold Heat Pump Water Heater

Models: 200 L / 300 L / 500 L (split type)

A split heat pump that moves heat from the air into your water tank, in 200, 300 and 500 L sizes.

We don't list prices online — every installation is different. Tell us about your home and we'll share a written quotation after a free survey.

  • Split design with outdoor heat pump unit and separate storage tank
  • Three capacities: 200, 300 and 500 litres
  • Quick heating option runs the heat pump and the heating element together
  • Magnesium anode helps protect the tank against corrosion
  • Titanium enamel coating on the tank for tough water conditions
  • Isolated condenser built to European safety standards
  • High efficiency compressor for faster heat exchange
  • Controller for temperature setting and shower scheduling; a wired remote is now offered
  • CFC-free refrigerant system
  • Warranty of 5 years on the inner tank and compressor, 2 years on the product (conditions apply)

Overview

A heat pump water heater works like an air conditioner in reverse. An outdoor unit draws heat from the surrounding air and passes it to the water in an indoor storage tank, so most of the energy comes from the air rather than from the electric supply.

The Racold range is a split design: a compact outdoor unit connects to a separate storage cylinder. It comes in three tank sizes, which makes it suitable for a large family home at one end and for hostels, guest houses or small commercial kitchens at the other.

A built-in electric heating element can run alongside the heat pump when you need hot water quickly, and the controller lets you set the temperature and plan shower times.

A good fit for

  • Large independent houses with several bathrooms
  • Hostels, PGs and guest houses
  • Hotels, resorts and small commercial kitchens
  • Homes with space for an outdoor unit and good airflow
  • Households looking to lower electricity use for hot water

Key specifications

Configuration
Split (outdoor unit + storage tank)
Capacities
200 L / 300 L / 500 L
CoP (as rated)
4.25 (200 L, 300 L); 4.40 (500 L)
Highest water pressure
8.5 bar (200 L, 300 L); 8 bar (500 L)
Backup heating element
2 kW (200 L); 3 kW (300 L, 500 L)
Refrigerant
R134A (200 L); R410A (300 L, 500 L)
Max temperature, with heating element
75 °C (200 L); 70 °C (300 L, 500 L)
Max temperature, heat pump mode
55 °C (300 L, 500 L)
Anode
Magnesium
Electrical supply frequency
50 Hz
Noise at 1 m
50 dB (200 L, 300 L); 54 dB (500 L)
Warranty
Inner tank 5 yrs, compressor 5 yrs, product 2 yrs

Racold heat pump water heater - technical parameters (tested at ambient 20 °C DBT / 15 °C WBT, water 15 °C to 55 °C)

Parameter200 L300 L500 L
ConfigurationSplitSplitSplit
CoP4.254.254.40
Highest water pressure (bar)8.58.58
Heating element (kW)233
RefrigerantR134AR410AR410A
Tank net weight, empty (kg)7090110
Tank dimensions (mm)Ø500 x 1716Ø620 x 1655Ø733 x 1820
Outdoor unit net dimensions (mm)780 x 300 x 543780 x 300 x 543975 x 420 x 603
Max temperature with heating element (°C)757070
Max temperature, heat pump mode (°C)-5555
Rated hot water output (L per hour)75110135
Power output (W)350052616200
Power input (W)82312391409
Noise at 1 m (dB)505054

Specifications are summarised from the manufacturer's published literature and may change. Please confirm the exact model with us before ordering.

Please note: The leaflet quotes up to 70% lower electricity use and a 4.40 CoP. The 4.40 figure is for the 500 L model only, and the savings figures come from the manufacturer's lab test conditions. Actual savings depend on usage, climate and tariff.

Choosing the right size

  1. 200 L generally suits a family home with a few bathrooms; 300 L suits larger households or a small hostel.
  2. 500 L is aimed at heavier, repeated demand such as hostels, hotels or kitchens; it also carries the leaflet's best CoP rating.
  3. Hot water output per hour is listed (75, 110 and 135 L/h) - check it against your peak morning demand, not only the tank size.
  4. The outdoor unit needs open space with free airflow; the 500 L unit is physically larger (975 x 420 x 603 mm).
  5. Mind Power can check your terrace or utility area and daily hot water use before recommending a size.
Read our full buying guide

Racold Heat Pump Water Heater: FAQs

How does a heat pump heat water without much electricity?

It uses electricity mainly to run a compressor and fan that move heat from the outside air into the tank, rather than creating heat directly. The more heat it moves per unit of electricity, the higher its CoP.

What does the 4.40 badge mean?

It is the Coefficient of Performance (CoP). The leaflet's footnote says this figure applies only to the 500 L model under lab test conditions. The 200 L and 300 L models are rated at 4.25 in the technical table.

Can I get hot water quickly on a cool or rainy day?

Yes. The quick heating option runs the electric heating element together with the heat pump, so you get hot water sooner than with the heat pump alone.

Where does the outdoor unit go?

It needs an open, ventilated spot such as a terrace, balcony or utility yard, connected to the tank by refrigerant piping. Mind Power can survey the site before installation.

What warranty is mentioned in the leaflet?

The leaflet lists 5 years on the inner tank and compressor and 2 years on the product. Terms and conditions apply, so confirm the details when ordering.

Enquire about Racold Heat Pump Water Heater

We reply on WhatsApp or call you back, usually the same day.

Your details are only used to respond to your enquiry.

More heat pump water heaters

Not sure what you need? We will come and check.

Book a free site survey anywhere in Ballari. We look at your roof, water source, usage and power situation, then recommend the right system and share a written quotation.

ProductsCallWhatsAppFree survey